AUREX i-line AFM: proven quality assurance for standard pipe extrusion.
AUREX i-line AFM: for pipes, tubes, cables up to diameters of 1000 mm.
AUREX i-line AFM scans with 4-36 measuring spots around the pipe circumference and effects a simultaneous wall thickness and diameter measurement (exterior/interior diameter). Measurement is done by static sensors.
Minimum wall thickness tolerances are obtained through successive control loops for weight per meter, thin points and thermal centering.
AUREX i-line AFM covers a diameter range of 10 - 1000 mm. The system is suitable for co-extruded products, i.e. for the measurement of individual layers.
The system in short.
AFM measuring chambers are flanged directly to the outlet of the vacuum calibration unit.
Technical data.
| Type | Measuring range[mm] | Number of sensors |
|---|---|---|
| AFM 160 | 10-160 | 4/6/8 |
| AFM 250 | 10-250 | 4/6/8 |
| AFM 400 | 32-400 | 8/16/24 |
| AFM 500 | 63-520 | 8/16 |
| AFM 630 | 90-630 | 8/16/24 |
| AFM 800 | 90-800 | 16 |
| AFM 1000 | 160-1000 | 36 |
| AFM 1200 | 400-1200 | 36 |
The strong points.
- Large measuring range
- Proven measuring and control principles
- Individual data evaluation on request